Malfunctioning Test Appratus
The Temperature Malfunction test is as per IS 15778 for CPVC Pipe. This Pipes are used for Hot water and Cold water supply lines. This is the reason for this test equipment to confirm the pipe quality for such an application.
Hexaplast Equipment comes with digitally controlled water bath and Temperature Malfunction setup with circulation pump.
- Water Bath Inner size: 42 X 20 X 42 inches inside
- Water Bath: Insulated wit PUF
- PID Digital Temperature controller
- PT 100 – Temperature controller
- Temperature Range: Ambient to 95°C
- Resolution: 0.1°C
- Digital Timer: Display 7 segment, 9999 hr/min or seconds can be set.
- Pressure Gauge – to display pressure in Bars (Digital Pressure gauge Optional)
- Pressure Range: 0 to 10 Bars
- Pressure Transducer: to control pressure precisely.
- Power: 230 V & 50 Hz
- Digital controls
- PID Temperature controller for precise control (HMI Option available)
- Water circulation with precise pressure as per Indian standard.
- The Display indicates the test pressure in bars.
- Temperature Range: up to 95°C
- Water Tank with inside body made of stainless steel.
- Outside body and structure made from mild steel with powder coating for long life.